Explain the instructions and precautions for the incubator

The incubator is a new fluorine-free design, international brand compressor and circulating fan, large LCD screen, easy to operate, high efficiency and low energy consumption. It not only promotes energy saving, but also has a long service life, which can reduce noise to a lower limit. Compared with traditional cryogenic equipment, the cooling time is reduced by more than 40%.

Specific characteristics of the incubator:

New fluorine-free design, international brand compressors and circulating fans, large LCD screen, easy to operate, high efficiency and low energy consumption. It not only promotes energy saving, but also has a long service life, which can reduce noise to a lower limit. Compared with traditional cryogenic equipment, the cooling time is reduced by more than 40%. Specific features:

1. It adopts high-quality mirror stainless steel inner tank. The box body is sprayed with high-quality steel plate, four corners and half arc, easy to clean, and the spacing of the partitions inside the box is adjustable.

2. On-screen LCD display, multiple sets of data on one screen, easy to understand, easy to observe and operate.

3. It is equipped with the most advanced fuzzy PID intelligent temperature controller in the world, with small fluctuation and timing function (0-9999min).

3. It has an independent temperature limit alarm system, which automatically interrupts when the temperature exceeds the limit temperature, ensuring safe operation of the experiment without accidents.

Precautions

1. Do not use the instrument when the battery indicator indicates that the power is exhausted. If you do not use the instrument for a long time, remove the battery and store it.

2. Do not store or use the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.

3. Use a damp cloth or detergent to clean the instrument case. Do not use abrasives or solvents.

4. When the instrument is wet, dry it and store it.

use

Applicable to environmental protection, health and epidemic prevention, drug testing, agriculture, livestock, aquatic products and other research, colleges, production departments, water body analysis and 800 determination, bacteria, mold, microbial cultivation, preservation, plant cultivation, breeding experiments dedicated thermostat equipment.

Instructions for use

Steps for usage

1. The incubator should be placed in a clean, tidy, dry and ventilated work space.

2. Before use, the control switches on the panel should be in non-working state.

3. Place test samples on the culture rack. When placed, keep appropriate intervals between the test bottles (or vessels) to facilitate convective circulation of cold (hot) air.

4. Turn on the external power supply and set the power switch to the "on" position. The indicator light is on.

5, choose the culture temperature

set temperature

Press the SET button to set the temperature, press the SET button to flash the data in the lower row of the digital tube, indicating that the meter enters the temperature setting state, press the â–³ button to increase the setting value, press the â–½ button to decrease the setting value, and then press the SET button. The meter returns to normal operation and the temperature is set.

Error correction

The displayed value can be corrected when it is confirmed that the value displayed by the meter is not the correct measured value. Press the SET button for 3 seconds to enter the inner menu of the meter. After selecting the parameter SC, use the â–³ or â–½ key to modify this parameter. The correction range of the sensor error is +50 to -50. After the correction is completed, press the SET button for 3 seconds to exit. When the instrument is shipped, the correction value is 0. When using it, it should be prevented from correcting the correct display to incorrect.

Start auto-tuning

The product can adapt to most control systems. Only when the control effect is particularly unsatisfactory, the self-tuning can be started. Press the SET button for 3 seconds to enter the inner menu of the instrument. After selecting the parameter At, the â–³ or â–½ key is used to start the auto-tuning. At this time, At The indicator light starts to flash and the instrument enters the auto tuning parameter working state. The meter control heating system pays close to the fluctuation twice at the set point. When the At lamp is off, the auto tuning is finished, and the new PID parameter is latched in the chip.

The company's main stainless steel water collector, tank bottom weld vacuum test box, reading instrument, eight-stage air microbial sampler, relay comprehensive tester, dual-wavelength scanner, coating thickness gauge, soil mill, tempered glass surface Flatness tester, sound sensor, portable electric water level gauge, network mouth flow meter, corrosion rate meter, portable scratch tester, freezing point tester, water quality tester, online ammonia tester, coating thickness gauge, coating Thickness gauge, soil pulverizer, digital thermometer, gas sampling pump, ceramic impact tester, automatic crystallization point tester, drug freezing point tester, reed switch tester, constant temperature water bath, gasoline root turn, gas Sampling pump, tempered glass tester, water quality tester, PM2.5 tester, inhalable particulate matter detector, high frequency heat sealing machine, strain control triaxial instrument, milk somatic cell detector, helium gas concentration detector, soil moisture conductance Rate tester, field strength meter, collection box, color ratio tester, capillary water absorption time measuring instrument, redox potentiometer vibrometer, carbon monoxide carbon dioxide detection , CO2 analyzer, oscillopolarograph, slime content tester, car starter power supply, automatic potentiometric titrator, portable thermometer, zirconia analyzer, reed switch tester, precision conductivity meter, TOC water quality analysis Instrument, microcomputer plasticity tester, wind direction station, automatic spotting instrument, soil oxidation reduction potentiometer, digital thermometer, portable total phosphorus tester, corrosion rate meter, constant temperature water bath, residual chlorine detector, free expansion rate meter , centrifuge cup, concrete saturated vapor pressure device, particle strength tester, Gauss meter, automatic film coating machine, safety valve grinding tool, weather station, kinesthetic orientation instrument, dark adaptation instrument, smell collector, rain gauge, four in one Gas analyzer, emulsion concentration meter, dissolved oxygen meter, temperature measuring instrument, thin layer planking device, temperature recorder, aging meter, noise detector, constant temperature and humidity chamber, split resistivity tester, initial viscosity and holding viscosity Tester, infrared carbon dioxide analyzer, hydrogen lamp, kinesthetic orientation instrument, constant temperature animal operating table, cooling fan, grease acid value detector, viscosity meter, colony counter, Weather station, rain gauge, Kjeldahl nitrogen analyzer, fluorescent whitening agent, the company adhering to the "customer first, forge ahead" business philosophy, adhere to the "customer first" principle to provide our clients with quality services. Welcome patrons!

Winter Thick Slippers

Thick Slippers,Winter Home Slippers,Winter House Slippers,Soft Winter Slippers

Ningbo Autrends International Trade Co., Ltd. , https://www.homefavorities.com